EasyManuals Logo

Fronius TTB 80 G User Manual

Fronius TTB 80 G
Go to English
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #148 background imageLoading...
Page #148 background image
Juego de cables
refrigerado por
gas –
THP 160i,
THP 220i,
THP 260i
THP 160i THP 220i
Corriente de soldadura de CC
a 10 min / 40 °C (104 °F)
35% DC
1)
/ 160 A 35% DC
1)
/ 220 A
60% DC
1)
/ 120 A 60% DC
1)
/ 170 A
100% DC
1)
/ 90 A 100% DC
1)
/ 130 A
Corriente de soldadura de CA
a 10 min / 40 °C (104 °F)
35% DC
1)
/ 120 A 35% DC
1)
/ 180 A
60% DC
1)
/ 90 A 60% DC
1)
/ 130 A
100% DC
1)
/ 70 A 100% DC
1)
/ 100 A
Largo
4.0 / 8.0 m
(13 ft. 1.48 in. / 26 ft.
2.96 in.)
4.0 / 8.0 m
(13 ft. 1.48 in. / 26 ft.
2.96 in.)
Circuito de voltaje abierto máximo
permitido (U
0
)
113 V 113 V
Tensión de cebado máxima permiti-
da (U
P
)
10 kV 10 kV
THP 260i
Corriente de soldadura de CC a 10 min / 40 °C (104 °F)
35% DC
1)
/ 260 A
60% DC
1)
/ 200 A
100% DC
1)
/ 150 A
Corriente de soldadura de CA a 10 min / 40 °C (104 °F)
35% DC
1)
/ 200 A
60% DC
1)
/ 160 A
100% DC
1)
/ 120 A
Largo
4.0 / 8.0 m
(13 ft. 1.48 in. / 26 ft.
2.96 in.)
Circuito de voltaje abierto máximo permitido (U
0
) 113 V
Tensión de cebado máxima permitida (U
P
) 10 kV
1)
DC = Ciclo de trabajo