Energy per user Under "Range", a list showing the consumption of the registered ID chips can be
called up via "Energy per user". By entering "Total", the list can be downloaded as
a *.csv file. The following data is displayed in the file:
-
Session number: Sequential number. A session is the period of time between
connecting and disconnecting the charging cable.
-
Session identifier: Unique identification number.
-
ID chip: Information about the registered ID chip. No entry if loaded without
ID chip.
-
ECO operating mode [%]: Proportion of the charged energy from Eco Mode
as a percentage.
-
Next Trip operating mode [%]: Proportion of the charged energy from Next
Trip Mode as a percentage.
-
Start: Start date and time from which the charging cable is connected.
-
End: End date and time when the charging cable is disconnected.
-
Total duration: Period of time during which the Wattpilot is in use.
-
Duration of active current flow: Period of time during which energy was be-
ing charged into the vehicle.
-
Max. power [kW]: Maximum power in kilowatts reached during charging.
-
Max. current [A]: Maximum current in amperes reached during charging.
-
Energy [kWh]: Indicates the charged energy in kilowatt hours.
-
PV energy [kWh]: Indicates the charged energy in kilowatt hours provided by
PV surplus.
-
Battery energy [kWh]: Proportion of the charged energy in kilowatt hours
provided by a stationary energy storage device.
-
Meter reading start [kWh]: Indicates the charged energy in kilowatt hours at
the start of the charge.
-
Meter reading end [kWh]: Indicates the charged energy in kilowatt hours at
the end of the charge.
48