Appendix-1
Ver.1.36
CONSUMABLE PARTS LIST
(Please visit our web site for photographs of each consumable part.)
1. Sample cup and related parts (All stainless steel sample cups treated by special deactivation process)
50 µL, id. 3.8 mm, deactivated stainless steel, contains 100 pcs
80 µL, id. 3.8 mm, deactivated stainless steel, contains 100 pcs
50 µL, id. 3.0 mm, glass, no quartz coating, contains 100 pcs
50 µL, id. 3.0 mm, quartz coated glass, contains 30 pcs
50 µL, id. 3.8 mm, deactivated stainless steel, hole at bottom, 20 pcs
80 µL, id. 3.8 mm, deactivated stainless steel, hole at bottom, 20 pcs
For Single-Shot, contains 50 pcs
For Double-Shot, contains 50 pcs
For Single-Shot with Eco cup G/GQ, contains 50 pcs
For Double-Shot with Eco cup G/GQ, contains 50 pcs
Stainless steel Eco cups retriever, contains 5 pcs
Eco cup G/GQ retriever, contains 5 pcs
Eco-cup stand (for all Eco-Cups), used when sampling, 5 pcs
Performance evaluation
polystyrene standard sample
Polystyrene 2.5mg film, Me-stearate 5wt.% , 2ml glass bottle.
2 g, covering the sample in the eco-cup or other universal use.
Quartz pyrolysis tube A30
Quartz pyrolysis tube for PY-3030
For liquid sampler, φ0.8mm, 1 ea
Silicon rubber for liquid sampler (pale yellow), contains 20 pcs
For sealing quartz pyrolysis tube, standard for EGA/PY-3030D, translucent
silicon rubber, contains 20 pcs
For sampler base, black, 10pcs
EGA/PY-3030D standard part. Deactivated.
Includes ITF union N(1ea), ITF needle(2ea) and Needle nut(1ea), 1 set
For Auto-Shot Sampler and EGA/PY-3030D, Deactivated.
Heat sink adapter kit 3030SA
For EGA/PY-3030D. Used for Agilent7890/6890 and Shimadzu GC-2010
/17A, includes 2 securing screws.
Heat sink adapter kit 3030PE
For EGA/PY-3030D. For PE Auto system/Clarus GC, includes 2 securing
screws.
Interface needle securing nut, contains 3 pcs.
Deactivated needle, contains 3pcs
6mm hole i.d., for interface, contains 5 pcs.
For tube connections, silicon rubber (pale yellow) with hole, contains 20
pcs.
for Agilent GC, Thermo TRACE 1300/1310GC injection port, surface treated,
5 ea
For injection port of Shimadzu GC, for pyrolysis only, contains 5 pcs, surface
specially treated.
For injection port of Agilent 6890 and 7890, surface deactivated, with
deactivated quartz wool.
Graphite O-ring (for Agilent)
Graphite O-ring for Agilent GC liners, 3 ea
For Shimadzu GC-17A/14A and GC-2010 split vent
For PY1-2227, Activated carbon filled trap tube only, contains 3 pc.
Metal capillary column connection kit for magnetic field MS.
Vent-free GC/MS Adapter N-50
Recommended for Agilent, JEOL, Shimadzu and Thermo TRACE 1300/1310
GC/MS,VF tube N-50 (50cm, 2 set) with, VF holder N (1ea), Column nut (2
ea), VF metal ferrule D (10 ea), Plug nut A (1ea), 1 set
Vent-free GC/MS Adapter N-70
Recommended for Thermo TRACE Ultra/Focus GC/MS, VF tube N-70 (70
cm, 2 set), Column nut (2 ea), VF holder N(1 ea), VF metal ferrule D(10 ea),
Plug nut A (1 ea), 1 set
Vent-free GC/MS Adapter
N-70PE
Recommended for PerkinElmer Clarus series,VF tube N-70PE (70cm, 2 set),
VF holder N(1 ea), Column nut (2 ea), VF metal ferrule D (10 ea), Plug nut A
(1 ea), 1 set
VF tube N-50, includes each one of Vent-free tube 0.15mm id / 50cm, VF
metal ferrule D (2 ea) and VF nut B (2 ea). For Agilent, JEOL, Shimadzu
and Thermo TRACE 1300/1310 GC/MS