Wind Pressure
When installed on the back of the antenna or installed on its own (away from the antenna), the RU is functional,
operational, and able to withstand winds in excess of 240 Km/hour (66.6 m/s).
Earthquake
Telcordia GR-63, Zone 4
Environmental Exposure
Gas Exposure IEC-60068-2-60
Test method: JIS-C-0048 Method-4
Criteria: Test piece is used. Rating 4 in JIS H8502.
Salt fog Telcordia GR-487
2.2.2
Transport and Storage Requirements
Packaged Equipment Shock Drop
Telcordia GR 63
Mass: < 40 kg Height 500 mm
Mass: < 50 kg Height 400 mm
Criteria Must not sustain any physical damage or deterioration in functional performance
Compliant with GR-63 standards
Storage Temperature
–33…+40 °C (91.4…104 °F)
Relative Humidity 15…100%
Absolute Humidity 0.26…25 g/m3
Change of Temperature 0.5 °C/min (32.9 °F/min)
Vibration
ETSI EN 300 019-2-4, Severity class 1
2.2.3
Product Safety Specication
Basic Specication UL62368-1 2nd edition
Outdoor Specication UL 50E (UL60950-22) CSA-C22.2
RU Hardware Feature
RU Specications
24
Release 1.0 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only