Other IP65 is supported for the function of waterproong with ed cap or connected cable.
No guarantee for waterproof when cap or cable is loose contact or not connected.
2.7.3
DC Power and Ground Ports
e RU has a 2-wire (–48V, Return) power connector for the power Input. An example of the RU power
connection and grounding is shown in the following gure.
6AWG
Ground Wire (FG)
SPD
RRH
PE SG
Return
Shield (FG)
DC (-48V)
Return
DC (-48V)
Isolated DC/DC
To RRH Internal Circuit
NOTE: SG, PE, 6AWG Ground Wire, and Shield are connected to RRH Chassis.
DC Power
Supply
RRH Metal Chassis = FG
2-Wire
P
ower Supply Cable
RRH - Remote Radio Head
SPD - Surge Protected Device
FG - Frame Ground
SG - Signal Ground
PE - Protected Earth
FNC001632_Rev_01
Figure 6
DC Power and Frame Ground Connection
Physical interface 10-752508-Z2P or the compatible connector of Amphe-BTS series is used.
e product number of external cable plug is 10-761296-Z2S for AWG shielded cable or
10-761297-Z2S for 7-5 AWG shielded cable.
Power cable length: 300 maximum. 6 AWG is required.
Electrical interface −36.0 to −58.0 V DC input (Normal −48V)
Other Lightning protection circuit on RU (Refer to Resistability of Lightning)
IP65 is supported with the function of waterproong with connected cable.
No guarantee for waterproof when cable is loose contact or not connected.
e RU to be shipped with a protective dust cap on the DC Power connector to protect
against dust and other small particles. e water ingress protection is not required for these
caps.
e RU has two M6 bolts and nuts for lug ground connection.