Table 6 (Cont.)
Specication In 3GPP 38.113
Phenomenon Application Reference Standard
Detail
Specication
Criteria
Electrostatic discharge Enclosure IEC 61000-4-2 Electric Discharge B
Fast transients common mode Signal, telecommunications and
control ports, DC power input
ports
IEC 61000-4-4 Fast Transients
Common Mode
B
RF common mode 0, 15…80 MHz Signal, telecommunications and
control ports, DC power input
ports
IEC 61000-4-6 RF Common Mode A
Surges, common and dierential
mode
AC power input ports,
telecommunications port
IEC 61000-4-5 Resistability of
Lightning
B
Radiated Immunity
Test Standard 3GPP 38.113
IEC 61000-4-3 Level 3
Test mode Trac mode, excludes receiver exclusion band.
80…6000 MHz 3 V/m, AM 80%
Performance Criteria A
Electric Discharge
Test standard 3GPP 38.113
IEC 61000-4-2
Contact discharge ±4 kV
Air discharge ±8 kV
Performance Criteria B
Fast Transients Common Mode
Test standard 3GPP 38.113
IEC 61000-4-4
0.5 kV
Performance criteria B
Injected port Power consistency, RET consistency
RU Hardware Feature
RU Specications
26
Release 1.0 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only