Figure 15
Securing Mounting Adapter Plate
Step 4
Torque the M10 x 30 bolts to 27 Nm.
✓ is task is complete.
4.5.4
Attach RU to Pole
is procedure describes how to aach a RU to a pole using a pole mount kit.
Prerequisites:
■ Loctite LB 8012 or equivalent lubricant applied to bolts
■ 17 mm socket
■ 13 mm socket
■ 5/8 in. wrench
■ Torque wrench
Installation
RU Installation