Product Safety
Approvals /
Certication
RU has been tested by a Nationally Recognized Testing Laboratory (NRTL). A test report issued by
a NRTL shows compliance against UL 50E Ed. 1-2007, CAN/CSA-C22.2 NO. 94.2-07 and required
encapsulation class.
2.2.4
Electromagnetic Compatibility
Conducted Emission
Power Port Unintentional radiation: CFR 47, Part 15B
Test mode: trac mode
RET Port Conducted emissions 3GPP 38.113
Test mode: trac mode
Radiated Emission
Unintentional radiation CFR 47, Part 15B
Test Standards 3GPP 38.113
Radio frequency radiation
exposure limits
CFR 47, Part 1.1310
Immunity Performance
Test standard 3GPP 38.113
Performance Criteria A e Equipment Under Test (EUT) must continue to operate as intended during
and aer test.
No degradation of performance or loss of functions.
Performance Criteria B Temporary loss of function is allowed, provided the function is self-recoverable.
Radio must meet performance criteria before and aer completion of test.
Immunity Specication
Table 6
Specication In 3GPP 38.113
Phenomenon Application Reference Standard
Detail
Specication
Criteria
RF electromagnetic eld (80…
6000 MHz)
Enclosure IEC 61000-4-3 Radiated Immunity A
RU Hardware Feature
RU Specications
25
Release 1.0 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only