Product Safety
Approvals /
Certication
RU has been tested by a Nationally Recognized Testing Laboratory (NRTL). A test report issued by
a NRTL shows compliance against UL 50E Ed. 1-2007, CAN/CSA-C22.2 NO. 94.2-07 and required
encapsulation class.
2.2.4
Electromagnetic Compatibility
Conducted Emission
Power Port Unintentional radiation: CFR 47, Part 15B
Test mode: trac mode
RET Port Conducted emissions 3GPP 38.113
Test mode: trac mode
Radiated Emission
Unintentional radiation CFR 47, Part 15B
Test Standards 3GPP 38.113
Radio frequency radiation
exposure limits
CFR 47, Part 1.1310
Immunity Performance
Test standard 3GPP 38.113
Performance Criteria A e Equipment Under Test (EUT) must continue to operate as intended during
and aer test.
No degradation of performance or loss of functions.
Performance Criteria B Temporary loss of function is allowed, provided the function is self-recoverable.
Radio must meet performance criteria before and aer completion of test.
Immunity Specication
Table 6
Specication In 3GPP 38.113
Phenomenon Application Reference Standard
Detail
Specication
Criteria
RF electromagnetic eld (80…
6000 MHz)
Enclosure IEC 61000-4-3 Radiated Immunity A