FUNCTION DETAILS13-5.
Functions
Compact
cassette
Slim duct Wall mounted Floor / Ceiling Floor
1) Filter sign
z z z z z
2) Ceiling height
z
- -
z
-
3) Outlet directions
z
- - - -
4) Vertical airow direction range control - - - -
z
5) Static pressure -
z
- - -
6) Room temperature sensor control for cooling
z z z z z
7) Room temperature sensor control for heating
z z z z z
8) Auto restart
z z z z z
9) Room temperature sensor switching
z z z z z
10) Remote controller custom code
z z z z z
11) External input control
z z z z z
12) Room temperature sensor switching (Aux.)
z z z z z
13)
Indoor unit fan control for energy saving for
cooling
z z z z z
1) Filter sign
Select appropriate intervals for displaying the lter sign on the indoor unit according to the
estimated amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
(
... Factory setting)
Function number Setting value Setting description
11
00 Standard
01 Long interval
02 Short interval
03 No indication
Intervals will differ depending on the Indoor unit type as follows.
Setting description
Comapact
Cassette
Slim Duct
Wall
Mounted
Floor /
Ceiling
Floor
Standard 2500 hours 400 hours
Long interval 4400 hours 1000 hours
Short interval 1250 hours 200 hours
2) Ceiling height
Select the appropriate ceiling height according to the place of installation.
(
... Factory setting)
Function number Setting value Setting description
20
00 Standard (2.7 m)
01 High ceiling (3.0 m)
In case of Cassette type models: The ceiling height values are for the 4-way outlet.
Do not change this setting in the 3-way outlet mode.
7000, 9000 Btu/h models cannot be installed in high ceilings.
Do not change this setting.