LED name LED status Meaning
CACHE
(green)
There is data in the cache memory of the ETERNUS AF.
READY
(green)
The ETERNUS AF is available for use.
● ETERNUS AF650 S3
An operation panel has LEDs, a Power switch, and setting change switches.
Figure 14 Operation Panel (Controller Enclosure for the ETERNUS AF650 S3)
1
2 4
3
With a fr
ont cover Without a front cover
POWER LED
IDENTIFY LED
FAULT LED
MAINTENANCE LED CACHE LED
READY LED REMOTE LED
1 Power switch
This switch is used to turn on or off the ETERNUS AF
.
2 MNT SW (maintenance switch)
This switch is used to switch the maintenance status on or off.
3 IP RST SW (IP reset switch)
This switch is used to initialize the LAN ports or to initialize the user information.
4 MST SW (CM Master Change switch)
This switch is used to change the Master CM.
The LEDs turn on or blink to indicate the statuses that are listed below.
Table 10 Status and Meaning of Each LED (Operation Panel [Controller Enclosure for the ETERNUS AF650
S3])
LED name LED status Meaning
POWER
(green)
Power is supplied to the controller enclosure.
IDENTIFY
(blinks blue)
The installation location of the controller is identified according to
the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI.
FAULT
(amber)
The ETERNUS AF is in error status.
(blinks amber)
A part of the ETERNUS AF requires preventive maintenance.
A. Component Names
Controller Enclosure
72 Operation Guide (Basic)