● About Static Electricity
• When handling SFP+ modules, make sure to wear a wrist strap or touch a
metal part to discharge the human body's natural static electricity.
Failure to discharge static electricity may cause device failure.
• Leave the SFP+ module in its package until ready to install it.
● About Shock
• Do not handle SFP+ modules roughly or subject them to physical shocks when
laying them down.
• Do not place any objects on top of SFP+ modules.
• Do not knock or drop SFP+ modules on hard objects.
Long Wave SFP+ Modules (16Gbit/s) Installation Procedure
This section describes how to replace a Short wave SFP+ module (16Gbit/s) in the host interface (FC 16Gbit/s)
with a Long wave SFP+ module (16Gbit/s).
• If SFP+ modules are installed in a way other than as described here, damage
and/or device failure or electrical shock may occur.
1 Check that all components of the
ETERNUS AF are in normal status, using the [Storage System Status]
screen of ETERNUS Web GUI.
2 Check the port location of the Short wave SFP+ module (16Gbit/s) that is to be replaced by using the
Internal Parts information in the [Channel Adapter Detail] screen.
Note that a Short wave SFP+ module (16Gbit/s) is displayed as "16G SFP+(MMF)" in the "SFP Type" field.
3 Turn off the ETERNUS AF.
Refer to "Powering Off" (page 19) for details on how to turn off the ETERNUS AF.
4 Wear a wrist strap or touch a metal part to discharge the human body's natural static electricity.
5 Disconnect the FC cable that is connected to the FC port in the Short wave SFP+ module (16Gbit/s) that is
to be replaced.
Push the tab on the FC cable connector and pull out the cable.
4. Component Expansion/Function Enhancement
Installing Long Wave SFP+ Modules (16Gbit/s)
49 Operation Guide (Basic)