● ETERNUS AF150 S3/AF250 S3
Figure 16 Controller (ETERNUS AF150 S3/AF250 S3)
IDENTIFY/BBU FAULT LED
D
I (OUT) LINK/FAULT LED
LAN ACT LED
LAN LINK LED
READY/FAULT LED
CA#0 FAULT LED
MASTER LED
CA#1 FAULT LED
LINK/FAULT LED
LINK/FAULT LED
LAN ACT LED
LAN LINK LED
Table 12 Status and Meaning of Each LED (Controller for the ETERNUS AF150 S3/AF250 S3)
LED name LED status Meaning
IDENTIFY/BBU FAULT
(blinks blue)
The installation location of the controller is identified according to
the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI.
(amber)
The battery is in error status.
DI (OUT) LINK/FAULT
(green)
The link between the DI (OUT) port and the destination port has been
established.
(amber)
• The link between the DI (OUT) port and the destination port is in
error status.
• The ports to remove the cables between enclosures from are
indicated. This occurs while a drive enclosure is being added.
(blinks amber)
The ports to connect the cables are indicated. This occurs while a
drive enclosure is being added.
READY/FAULT
(green)
The controller is in normal status.
(blinks green)
An error has occurred during startup.
(amber)
• The controller is performing the initial setup after the power is
turned on.
• The controller is in error status.
(blinks amber)
MASTER
(green)
The controller is set as a Master CM.
CA FAULT
(amber)
The host interface is in error status.
LINK/FAULT
(green)
The link between the host interface port and the destination port has
been established.
(amber)
The host interface port is in error status.
LAN ACT
(blinks green)
Data is being sent or received via the LAN port.
A. Component Names
Controller Enclosure
74 Operation Guide (Basic)