Short wave SFP+ modules (16Gbit/s) and Long wave SFP+ modules (16Gbit/s) can be mixed in the same host
interface (FC 16Gbit/s).
The SFP+ module configuration must be the same for controller 0 (CM#0) and controller 1 (CM#1).
Installable Long Wave SFP+ Modules (16Gbit/s)
For installable Long wave SFP+ modules (16Gbit/s), refer to "Product List".
SFP+ Module Handling Instructions
● About Condensation
•
When moving an SFP+ module from a cold place, such as an un-conditioned store
house in winter, to a warmer places such as an air-conditioned room, the severe tem-
perature change may result in condensation forming.
To avoid this, allow the packed SFP+ modules sufficient time in the warmer place (one
hour for each 15
°C of temperature difference) to adapt to the new temperature.
● About Static Electricity
•
When handling SFP+ modules, make sure to wear a wrist strap or touch a metal part to
discharge the human body's natural static electricity.
Failure to discharge static electricity may cause device failure.
•
Leave the SFP+ module in its package until ready to install it.
● About Shock
•
Do not handle SFP+ modules roughly or subject them to physical shocks when laying
them down.
•
Do not place any objects on top of SFP+ modules.
•
Do not knock or drop SFP+ modules on hard objects.