7 Add the results in the "WWN instance management table for the server".
Example:
Physical slot
name
WWN
Controller num-
ber
Instance name Physical path name
PCIE 0 210000e08b126d70 c4 qlc0 /pci@9,600000/SUNW,qlc@1
PCIE 1 210000e08b16cffd c5 qlc1 /pci@9,600000/SUNW,qlc@2
This completes the "WWN instance management table for the server".
1.3.1.2 Setting the Configuration File (/etc/system)
1 Edit the configuration file.
Edit the configuration file (/etc/system) and specify the command queue depth.
The appropriate command queue depth is determined by the ETERNUS DX/AF model, as follows:
Model
Setting value
Command queue depth
ETERNUS DX/AF Arbitrary (*1)
(Up to 1024 for each FC port of the ETERNUS DX/AF)
*1: Recommended value = 1024 ¸ (number of Fibre Channel ports that are connected to a single CA
port) ¸ number of LUNs
(Round the result down)
Use the value of "8" if the actual result is lower.
To achieve maximum system performance, this value can be changed according to the server
load and the peak operating times.
The number of simultaneous command executions per CA port for the ETERNUS DX/AF is limited
to 1024. This value is used by multiple servers that share the CA port. A maximum of 1024 com-
mands can be executed per CA port.
For the ETERNUS DX/AF
The parameter to be specified for the command queue depth is determined by the CPU which is in-
stalled in the server to be connected.
- For SPARC
Specify the command queue depth for the "ssd_max_throttle" parameter.
Add this parameter if it does not exist.
Example:
set ssd:ssd_max_throttle = 20
Chapter 1
Operations When Using Oracle Fibre Channel Cards
1.3 Setting Up the Server
12
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
Copyright 2017 FUJITSU LIMITED