2.5.2 For Driver Versions Before V6.30g
Edit the configuration file according to the following parameter list.
2.5.2.1 lpfc.conf Parameter Values
Parameter
Setting value
(for direct connection)
Setting value
(for switch connec-
tion)
lpfcX
(Instance name)
Remarks
log-verbose 0x0 0x0 — —
log-only 1 1 — —
lpfcX-fcp-bind-method 4 2 Yes An instance name is
specified for each in-
stance.
fcp-bind-WWNN Not required Not required — —
fcp-bind-WWPN Not required (*1) — —
fcp-bind-DID Not required Not required — —
lpfcX-automap 1 0 Yes An instance name is
specified for each in-
stance.
lun-queue-depth
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2: Not re-
quired
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: 20
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2: Not re-
quired
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: 20
— —
tgt-queue-depth
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2: Not re-
quired
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: 512
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2: Not re-
quired
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: 512
— —
lpfcNtM-lun-throttle Not required Not required — —
lpfcNtM-tgt-throttle
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2: 40
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: Not re-
quired
•
For the ETERNUS
DX60 S2/DX80 S2/
DX90 S2:
40 ¸ (No. of Server-
side Fibre Channel
ports connected to
each ETERNUS-side
CA port) (Round the
result down)
Use the value of "8" if
the actual result is
lower.
•
For the ETERNUS
DX400 S2 series and
the ETERNUS DX8000
S2 series: Not re-
quired
—
—
no-device-delay 0 0 — —
network-on 0 0 — —
Chapter 2 Setup Procedure for Emulex Fibre Channel Cards
2.5 Required Driver Parameters
47
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
Copyright 2017 FUJITSU LIMITED
P3AM-6312-18ENZ0