Setting Up the Server to Recognize the Logical Units (LUNs)
Make the server recognize the ETERNUS DX/AF logical units using the sd driver.
•
"3.4 Setting Up the Server to Recognize the Logical Units" (page 63)
After completing all the required procedures in this manual, proceed to "Setting the Multipaths" in
"Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris".
3.2 Installing the Fibre Channel Card Driver
Use the following procedure to install the Fibre Channel card driver.
1 Download and install the appropriate driver from the QLogic web-site:
http://www.qlogic.com (QLogic web-site)
Installation procedures should be available with the driver.
2 Download and install the "SANsurfer FC HBA CLI Application" from the QLogic web-site.
3.3 Setting Up the Server
The server setup will vary according to how the ETERNUS DX/AF storage systems and server are to be connec-
ted. Edit the server's configuration file to match the chosen topology. Configuration files may also differ de-
pending on which Fibre Channel cards are to be used.
There are two possible connection topologies: direct connection and switch connection.
● For direct connection
Instance name data of the Fibre Channel card is necessary. Refer to the following sections to set.
•
"3.3.1 Creating a WWN Instance Management Table for the Server" (page 56)
•
"3.3.2 Creating a WWN Instance Management Table for Storage System" (page 60)
•
"3.3.4 Setting the Configuration File" (page 62)
•
"3.3.5 Re-checking the Settings" (page 62)
Chapter 3
Setup Procedure for QLogic Fibre Channel Cards
3.2 Installing the Fibre Channel Card Driver
55
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
Copyright 2017 FUJITSU LIMITED
P3AM-6312-18ENZ0