5 Add the results in the "WWN instance management table for the server".
Example:
Physical slot
name
WWN
Controller num-
ber
Instance name Physical path name
PCIE1 100000051ee7457b bfa0 /pci@7c0/pci@0/pci@8/bfa@0
PCIE2 100000051ee7457c bfa1 /pci@7c0/pci@0/pci@8/bfa@0,1
6 Check the controller number of the target connected to the Fibre Channel card.
Use the following command to check the controller number of the target connected to the Fibre Chan-
nel card. The controller number corresponds to the physical path displayed in Step (1).
# cfgadm -v
Example:
Ap_Id Receptacle Occupant Condition Information
When Type Busy phys_ID
c2 connected configured unknown
unavailable fc-fabric n /devices/pci@7c0/pci@0/pci@8/bfa@0/fp@0,0:fc
c3 connected configured unknown
unavailable fc-fabric n /devices/pci@7c0/pci@0/pci@8/bfa@0,1/fp@0,0:fc
7 Add the results in the "WWN instance management table for the server".
Example:
Physical slot
name
WWN
Controller num-
ber
Instance name Physical path name
PCIE1 100000051ee7457b c2 bfa0 /pci@7c0/pci@0/pci@8/bfa@0
PCIE2 100000051ee7457c c3 bfa1 /pci@7c0/pci@0/pci@8/bfa@0,1
This completes the "WWN instance management table for the server".
4.3.2 Setting Up the Fibre Channel Cards
Brocade Command line Utility (BCU) is bundled with the Brocade Fibre Channel card driver.
Use the "bcu" command to check the port ID and to set the port speed, topology, and frame data size.
•
Port ID
Use the information obtained in "4.3.1 Creating a WWN Instance Management Table for the Server" (page
75) to check the port ID.
Port ID check command
bcu port --list
Chapter 4
Operations When Using Brocade Fibre Channel Cards
4.3 Setting Up the Server
77
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
Copyright 2017 FUJITSU LIMITED
P3AM-6312-18ENZ0