Port speed
Specify the port speed value according to the table below.
"bcu" command format
bcu port --speed <port_id> [ 1|2|4|8|16|10|auto]
Fibre Channel
card transfer rate
Fibre Channel switch transfer rate
Direct connection
to Fibre Channel
cards
16Gbit/s 8Gbit/s 4Gbit/s 2Gbit/s 16Gbit/s CA
16Gbit/s 16 8 4 — —
8Gbit/s 8 8 4 2 —
4Gbit/s 4 4 4 2 —
•
Topology
Set the topology value to "p2p".
"bcu" command format
bcu port --topology <port_id> [auto | p2p]
•
Frame data size
Set the frame data size value to "2048".
"bcu" command format
bcu port --dfsize <port_id> [<dfsize>]
The following procedure shows an example for setting the port speed, topology, and frame data size.
1 Check the "port_id" of the target port.
# bcu port --list
Port# Type PWWN/MAC FC Addr/ Media State Spd
Eth dev
1/0 fc 10:00:00:05:1e:e7:45:7b 010400 sw Linkup 8G
1/1 fc 10:00:00:05:1e:e7:45:7c 010500 sw Linkup 8G
The underlined portion indicates the port ID.
The port ID checked here is used to set the port speed, topology, and frame data size.
2 Set the port speed to "8G".
# bcu port --speed 1/0 8
Setting will be enforced after port --disable and -enable
Chapter 4
Operations When Using Brocade Fibre Channel Cards
4.3 Setting Up the Server
78
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
Copyright 2017 FUJITSU LIMITED
P3AM-6312-18ENZ0