EasyManua.ls Logo

Fujitsu ETERNUS DX - Page 78

Fujitsu ETERNUS DX
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Port speed
Specify the port speed value according to the table below.
"bcu" command format
bcu port --speed <port_id> [ 1|2|4|8|16|10|auto]
Fibre Channel
card transfer rate
Fibre Channel switch transfer rate
Direct connection
to Fibre Channel
cards
16Gbit/s 8Gbit/s 4Gbit/s 2Gbit/s 16Gbit/s CA
16Gbit/s 16 8 4
8Gbit/s 8 8 4 2
4Gbit/s 4 4 4 2
Topology
Set the topology value to "p2p".
"bcu" command format
bcu port --topology <port_id> [auto | p2p]
Frame data size
Set the frame data size value to "2048".
"bcu" command format
bcu port --dfsize <port_id> [<dfsize>]
The following procedure shows an example for setting the port speed, topology, and frame data size.
1 Check the "port_id" of the target port.
# bcu port --list
Port# Type PWWN/MAC FC Addr/ Media State Spd
Eth dev
1/0 fc 10:00:00:05:1e:e7:45:7b 010400 sw Linkup 8G
1/1 fc 10:00:00:05:1e:e7:45:7c 010500 sw Linkup 8G
The underlined portion indicates the port ID.
The port ID checked here is used to set the port speed, topology, and frame data size.
2 Set the port speed to "8G".
# bcu port --speed 1/0 8
Setting will be enforced after port --disable and -enable
Chapter 4
Operations When Using Brocade Fibre Channel Cards
4.3 Setting Up the Server