Chapter 5 Setup
5.2 ETERNUS DX Disk Storage System Monitoring Setup
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Installation-
Copyright 2013 FUJITSU LIMITED P3AM-4832-07ENZ0
130
6 Download the MIB file.
Download the MIB file that is registered in the ETERNUS DX Disk storage system.
6-1 In [Action], click [Download MIB File].
The [Download MIB File] screen appears.
6-2 In the [Download MIB File] screen, set the required items and click the [Download] button.
A confirmation screen appears.
6-3 Click the [OK] button.
A dialog box to download the file appears.
6-4 Click the [Save] button.
The MIB file is saved.
6-5 Check the setting completion message and click the [Done] button.
The screen display returns to the [Network] screen.
End of procedure
â–  Monitoring server settings
Install and set up the monitoring software on the server side.
Refer to the manual that is provided with the monitoring software to install and set the monitoring software.
Select the "The ServerView control code is added to the comment line of the MIB definition file"
checkbox when downloading the MIB file for monitoring the ETERNUS DX Disk storage system by
ServerView.
Register the file that was downloaded in Step 6 of "ETERNUS DX Disk storage system settings" as the MIB
definition file for the monitoring software.