42 Service Supplement RX200 S6
Replacement routines
Installing the new system board
Ê Insert the system board by holding it at a slight angle.
Ê Carefully shift the system board to the rear of the server until the connectors
engage with the cut-outs in the connector panel.
Ê Lower the system board carefully into the housing.
Ê Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion.
I When the system board is in the right position, the centre rings (see
red circles in figure 20) engage with the holes indicated.
Ê Fasten the system board with the seven screws (see blue circles in
figure 20).
Ê Reinstall the spacer screw (see figure 18).
Ê Reinstall the fan box and fasten it with the two screws (see circles in
figure 19).
Ê Reinstall all fan units (description see the Operating Manual).
Ê Reconnect all cables to the system board (see the cabling plans in the
Appendix of the Options Guide).
Ê If available, reinstall the TPM (see the section "Replacing the TPM" on
page 30).
Ê If available, reinstall the UFM (see the section "Replacing the UFM" on
page 32).
Ê Reinstall the riser card holders (see the Options Guide).
Ê Reinstall the CPU heat sinks (see the Options Guide).
Ê Reinstall the memory modules (see the Options Guide).
Ê Reinstall the air duct (see the section "Installing the air duct" on page 26).
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
Ê Reconnect all external cables.