52 Options Guide RX300 S6
Processors
Figure 24: Installing the heat sink
Ê Close the two heat sink retention levers at the same time.
Ê Replace the air duct over the main memory (see section "Inserting the air
duct" on page 120).
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter "Completion" on page 117.
6.3 Replacing the heat sink
Ê Open the server as described in section "Opening the server" on page 29.
Ê Remove the air duct over the main memory and processors (see section
"Removing the air duct" on page 30).
Ê Open the two heat sink retention levers at the same time (see section
"Replacing the processor" on page 49).
Ê Loosen the heat sink by turning it back and forth and then lift it out.
Ê Clean the upper side of the processor using a lint-free cloth.
Ê Remove the protective cover from the new heat sink.

Related product manuals