90 Options Guide RX300 S6
Expansion cards and BBU
8.1 Installing expansion cards
I The system board offers seven low profile PCI slots:
There are no hot-plug slots.
In the standard setup, slot 1 is populated with a SAS/SATA RAID
controller.
You will find an overview of the slots in the technical manual for the
system board D2619-N.
Ê Open the server as described in chapter "Preparation" on page 27.
Figure 66: Removing the slot cover
Ê Remove the screw from the slot cover of the slot you want to equip.
Ê Remove the slot cover.
V CAUTION!
Keep the slot cover of the PCI slot. If you remove the controller again
and do not replace it with a new one, the slot cover must be
reinstalled to comply with EMC regulations and to satisfy cooling
requirements and fire protection measures.