54 Operating Manual TX200 S5
Connecting the server to the mains Installing the hardware
Connecting the monitor
Ê Connect the monitor to the standard port of the server (see figure 7 on
page 53).
Ê Connect the power cable of the monitor to a grounded mains outlet of the in-
house mains and/or to the mains socket strip of the rack.
V CAUTION!
The rated current for the monitor is indicated on the technical data label
on the monitor or in the operating manual for the monitor.
4.5 Connecting the server to the mains
In the basic configuration, the server has a fixed power supply unit.
As an option, this power supply unit can be replaced with a hot-plug power
supply unit. A second hot-plug power supply unit can be added to ensure a
redundant power supply. If a defect occurs in one power supply unit, the other
power supply unit ensures unimpaired further operation.
V CAUTION!
The server adjusts itself automatically to a mains voltage in the range
100 V - 240 V. Make sure that your local mains voltage is within this
range.
I A phase redundancy in the power supply of the server can be set up if
two hot-plug power supply units are installed.
In this case the two power supply units are directly connected either to
two different phases or two different power circuits of the in-house mains.