22 Operating Manual TX200 S5
Technical data Preface
1.5 Technical data
Electrical data
Compliance with regulations and standards
Rated voltage range 100 V - 240 V
Frequency 50 Hz - 60 Hz
Rated current with basic configuration 100 V oder 240 V / 1.3 A - 0.6 A
Max. rated current 100 V - 127 V oder 200 V - 240 V /
9.5 A - 4.0 A
Effective power max. 461 W
Apparent power max. 490 VA
Heat dissipation 1660 kJ/h (1573 BTU)
Main power fuse 16 A
Protection class I
Product safety and
ergonomics
IEC 60950-1 / EN 60950-1, UL/CSA 60950-1,
CNS 14336 / GB 4943 / EN 50371
Electromagnetic
compatibility
FCC class A
CNS 13438 class A; VCCI class A
AS/NZS CISPR 22 class A / GB 9254 class A
GB 17625
interference emissions EN 55022 class A
Harmonic current EN 61000-3-2
Flicker EN 61000-3-3
interference immunity EN 55024, EN 300386
CE marking
to EU directives
Low Voltage Directive 2006/95/EC
(product safety)
Electromagnetic compatibility 2004/108/EC
Mechanical environmental
conditions
EN 60721-3-3; class 3M2