TX200 S5 Operating Manual 83
Troubleshooting and tips Added drive reported as defective
7.8 Added drive reported as defective
RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê Remove and reinstall the drive while the system is switched ON.
If the hard disk drive continues to be shown as defective, then replace it (see
“Hot-plug hard disk drives” on page 87).
7.9 Error message on screen
The meaning of the error message is explained in the documentation for the
relevant components and programs on the PRIMERGY ServerView Suite