Figure 4-13: Install the power cable locker
17. Login to the spare device via serial connection.
18. Set the IP-address to belong to the same segment as the PC(FST-S) to the
management port of the spare device.
19. Upgrade firmware.
Update the firmware of the spare device to the latest version of the firmware.
However, if the device was used as VPC switch, match the version of the
firmware of the spare device to the same as the peer switch.
20. 【System Administrator】Restore configuration file.
21. If SNTP server is not valid, set the time manually to the spare device.
22. Connect all the network cables to the switch ports.
23. Check the system status.
Check the firmware version with the show version command.
Command Execution Example
(ET-7648BRA-FOS) #show version
Current Runtime Version........................ 1.0.8
Current Runtime Build Time..................... Wed Jun 21 11:07:38 CST 2017
First Runtime Version.......................... 1.0.8
First Runtime Build Time....................... Wed Jun 21 11:07:38 CST 2017
Second Runtime Version......................... 1.0.5
Second Runtime Build Time...................... Fri Jun 9 15:23:27 CST 2017
Diagnostic Program Version..................... 1.0.0
ONIE Version................................... 1.0.0
Bootloader Version............................. 1.0.1
Please confirm that the “Current Runtime Version” is the updated firmware version
number.