controller.
Column:
MAC: This switch does not support multicast packet forwarding. Hence, only reserved
address “unknown-dst” is meaningful for BUM packets.
logical_switch: This column map to a row of logical switch table.
Locator_set: The physical locator set contain one or more local VTEP.
ipaddr: The IP address to which this MAC corresponds.
Physical_Locator_Set Table
This table includes a set of one or more physical locators.
Column:
locators: Set of 1 or more physical locators. Each of entry maps to a row of physical locator
table.
Physical_Locator Table
This table includes local and remote VTEP IP addresses.
Column:
encapsulation_type: Must be “vxlan_over_ipv4”.
dst_ip: VTEP IPv4 address.
Supported configurable Tables
The following columns of each table are supported to configure hardware VTEP
from OVSDB client application.
Table
Column
Physical_Switch
name
description
Physical_Port
description
vlan_bindings
Logical_Switch
name
description
tunnel_key