EasyManuals Logo

Furuno FELCOM 250 User Manual

Furuno FELCOM 250
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #186 background imageLoading...
Page #186 background image
FURUNO
FELCOM 250/500
SP - 2 E5666S01G-M
5 POWER SUPPLY
5.1 Communication unit 12-24 VDC: 9.2-4.6 A (transmit), 2.0-1.0 A (receive)
5.2 Handset PD class 2, 5 W or less
5.3 Incoming indicator PD class 1, 2 W or less
5.4 AC/DC power supply unit (PR-240, option)
100-115/200-240 VAC, 1 phase, 50/60Hz
6 ENVIRONMENTAL CONDITION
6.1 Ambient temperature
Exposed equipment: -25°C to +55°C (storage: -40°C to +70°C)
Protected equipment: -25°C to +55°C
6.2 Relative humidity 95% at 40°C
6.3 Degree of protection
Antenna unit IP56
Communication unit IP22 (tabletop mount with a connector cover and grommets)
Handset IP22 (cradle: IPX0)
Incoming indicator IP22
6.4 Vibration IEC 60945
6.5 Motion Roll: ±30°/8s, Pitch: ±10°/6s, Yaw: ±8°/50s, Rotation: 6°/s,
Speed: 30 kn
7 UNIT COLOR
7.1 Antenna unit N9.5
7.2 Communication unit N2.5
7.3 Handset/ cradle N2.5
7.4 Incoming indicator N2.5

Table of Contents

Other manuals for Furuno FELCOM 250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 250 and is the answer not in the manual?

Furuno FELCOM 250 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 250
CategoryMarine GPS System
LanguageEnglish

Related product manuals