1-1
1. MOUNTING
1.1 Display Unit
When selecting a mounting location for GP-170, keep in mind the following points.
• Keep the display unit out of direct sunlight.
• Locate the unit away from air-conditioner or heater.
• The temperature at the mounting location shall be between -15°C and +55°C.
• Locate the unit away from exhaust pipes and vents.
• The mounting location should be well ventilated.
• Mount the unit where shock and vibration are minimal (comply with IEC 60945
Ed.4).
• Keep the display unit away from equipment that generates electromagnetic fields,
such as motor, generator.
• For maintenance and checking purposes, leave sufficient space around the unit and
leave slack in cables. Minimum recommended space is shown in the outline draw-
ing for the display unit.
The GP-170 can be flush mounted in a console or panel, or mounted on a desktop.
Refer to the outline drawing at the end of manual.
1.1.1 Table top mounting
Mount the display unit on a desktop using the hanger.
NOTICE
Do not apply paint, anti-corrosive sealant or contact spray to
coating or plastic parts of the equipment.
Those items contain organic solvents that can damage coating and
plastic parts, especially plastic connectors.