PRE-DELIVERY INSPECTION PROCEDURE
1-12
25. ENGINE STOPPING PERFORMANCE
Turn the starter switch to “ACC” to see if the
engine stops at once.
Flick the emergency engine stop switch to the
“ON” position to see if the engine stops at once.
26. ELECTRICAL WIRING CONNECTIONS AND
ROUTING
Check the battery cable and other electrical wir-
ing connections for tightness.
Visually check the electrical harness routings.
Correct on necessity.
27. BRAKE RESERVOIR TANK FLUID LEVEL
Check the fluid level in the reservoir tank. The
fluid level should be between the level lines
“MAX” or “H” and “MIN” or “L”. If the level is too
low, check for fluid leaks.
28. FUEL LEAKS FROM FUEL TANK
Check for fuel leaks from the drain plug of the
fuel tank, the pipe connections and the seam.
Z22627
FUSO ASCENT-ALEJANDRO CANTO