EasyManua.ls Logo

FUTABA 32MZ-WC - GOV. Expert (Governor Expert Setting); (6) Revo. Up Dly: Revolution change up delay; (7) Revo. Dn Dly: Revolution change down delay; (8) Start Dly: Start delay

FUTABA 32MZ-WC
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
221
Model Menu (Helicopter)
ڀ ŪŲŃƗƒŃŷŤťůŨŃŲũŃŦŲűŷŨűŷŶ
+(/,&237(5
GOV.Expert(GovernorExpertSetting)
GOV.Expert(GovernorExpertSetting)
(6) Revo. Up Dly: Revolution change up delay
HowquicklytheRPMchangeswhenincreasingRPMbetweentwodiffer-
entRPMconditionsandflightmodes.AhighernumberslowstheRPM
changerate;alowervaluespeedsuptheRPMchangerate.
Settingranges:2~40
FrmInitialvalue:8
Frm
(7) Revo. Dn Dly: Revolution change down delay
HowquicklytheRPMchangeswhenreducingRPMbetweentwodiffer-
entRPMconditionsandflightmodes.Ahighernumberslowsthe RPM
changerate;alowervaluespeedsuptheRPMchangerate.
Settingranges:2~40
FrmInitialvalue:10
Frm
(8) Start Dly: Start delay
HowquicklytheRPMstabilizestothesetRPMfromwhentheGOVis
turnedON.Ahighervalueslowsdownthespooluprate;alowervalue
speedsupthespooluprate.
Settingranges:2~20
FrmInitialvalue:5
Frm
(9) Gov. On. Revo: Governor ON revolution setting
Thisparametertellsthegovernoratwhatpercentageofthesetrpmitis
tobecomeactive.Thedefaultvalueis60%.Inthiscase,thegovernorwill
notengageuntiltheenginerpmreaches60%ofthesetrpm.Ifyoufeel
thatthetimeforgovernorengagementistooslow,decreasethevalueto
50~55%.Thestartingtimewillbefaster.
Settingranges:50~90%Initialvalue:60%
(10) BFS. Volt: Battery F/S voltage setting
Thisparametersetsthebatteryfailsafeandlowbatteryalarmvoltage
levels,orthresholds.Setthepropervoltageasdeterminedbythebat
-
terytype.Thebatterycharacteristicsaredifferentdependingoncell
type/chemistry.
Suggestedsettingvoltagesareasfollows.
•4cellsNiCdorNiMH(Normal:4.8
v)=3.8
v
•2cellsLiFe(Normal:6.6
v)=6.0~6.2
v
•2cellsLiPo(Normal:7.4
v)=7.2~7.4
v
(11) Low. Revo: Low revolution setting
ThisvalueissettoassignthelowestpossiblegoverningRPM.IftheRPM
isbelow,orcannotreachthisRPM,thegovernorwillnotengage.Select
betweeneither1,000
rpmor700
rpm.Itcorrespondsalsotoahelicopter
witharotorspeedof1,000
rpmorless,suchasalargegasmachine.
Setting:700/1,000
rpmInitialsetting:1000
rpm
(12) RESET : Governor expert data reset
Thisresetsthe"GOV.EXPERT"settingbacktothedefaults.

Table of Contents