Page 64
Latch Any
Will activate when panel is set and will reset when entry timer starts.
Any Set
Will activate when panel is set and will reset when panel is unset.
Power Fail
Will activate when aux. power falls below 10.6 volts.
Power OK
Output is active and changes over when the battery volts fall below 10.6 V.
Watchdog
Will activate when the processor is reset.
Mails Fail
Will Activate when the mains is removed from the panel and will reset when the mains
is restored.
Any Digi
Will activate when any Digicom channel is triggered.
Status
This output has 3 operating modes intended to provide visual indication of system
status.
Set output on for 10 seconds.
Unset On for 1 second Off for 1 second for a 10 second period.
Confirmed On for 3 seconds Off for 1 second until the system is reset.
Perimeter
Will activate when a perimeter zone is triggered.
Zone Exclude
Will activate when the panel auto rearms with a zone in fault condition.
Custom 1-8 872 + 816 Only
This output can be used to follow a zone or code.
Timed 1-3
This output will follow the programmed On /Off times for times 1/2/3.
Any Closed
This output will change over when any area is set.
PR5892 Rev11 800 Series Eng Ref 15.qxd 16/11/2006 11:20 Page 64