Instructions for SL500DCL/SL800DCL
www.gatexpertstore.com
Acceleration Setting (L2)
Due to the different installation environment and gate installation status, users can adjust
the acceleration of starting and deceleration of buffering of the gate opener to their
necessary.
A. Operation Instruction:
1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on.
2. Press “PROG” button again for 3 sec. to enter into advanced menu. Indicator light L0
will flicker twice, then L1 will be steady on.
3. Press “+” button once to select acceleration. Indicator light L2 will be steady on.
4. Press “SET” button once to enter into acceleration setting. Indicator lights L1-L5 will
show the current acceleration value. (The default is L2)
5. Press “+” or “-” button to set the acceleration value. Indicator lights L1-L5 will indicate
the different acceleration values. The more the indicator lights will be on, the faster the
speed changes.
6. Press” SET” button once to save and system will automatically exit. The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off.
B. Operation Graphic Illustration
L0 flicker once, L1
will be steady on
Press “PROG”
again for 3 sec.
L0 flicker twice, L1
will be steady on
Press “+” or “-” to set, LED
will show the setting value
L1-L5 will be on in
sequence then all
flicker once and off.