239 Motor Protection Relay
CAUSE OF LAST TRIP:
MECHANICAL JAM
C US
Question and Answer IconNeed help?

Do you have a question about the GE 239 and is the answer not in the manual?

GE 239 Specifications

General IconGeneral
Current Rating10 A
Operate Time15 ms
Mechanical Life10, 000, 000 operations
Contact ConfigurationDPDT (Double Pole Double Throw)
Electrical Life100, 000 operations

Summary

Overview

Specifications

Provides detailed technical specifications for the 239 relay's electrical and performance parameters.

Installation

External Connections

Describes the terminal connections for wiring the 239 relay's inputs and outputs.

Programming

Setpoint Entry Methods

Outlines the methods available for entering setpoints into the 239 relay.

S1: 239 Setup

Covers user preferences, RS485 communication, and factory defaults for the 239 relay.

S2: System Setup

Details setpoints for CT inputs, ground sensing, and motor data configuration.

S3: Output Relays

Explains the programming of the relay's trip, alarm, and auxiliary output functions.

S4: Protection

Configures protection settings such as overload, phase S/C, and mechanical jam.

S5: Testing

Covers test configurations, relay/LED tests, and simulated current/output tests.

239PC Software

Installing/Upgrading 239PC

Guides users through installing or upgrading the 239PC software.

Configuring 239PC

Details the steps for establishing communication between 239PC and the relay.

239 Firmware Upgrade

Provides instructions for saving setpoints and loading new firmware into the relay.

Communications

Modbus Protocol

Describes the Modbus RTU protocol implemented by the GE Multilin 239 relay.

Testing

Primary Injection Testing

Describes how to verify system operation by injecting current through CTs.

Secondary Injection Testing

Outlines setup for testing relay operation and firmware interaction via secondary injection.

Phase Current Accuracy

Details steps to test the accuracy of phase current readings within ±2% scale.

Phase Current Overload

Guides testing of the phase current overload trip function and thermal capacity.

Phase Unbalance Alarm

Describes how to test the phase unbalance alarm feature and calculate % unbalance.