3.10.4 O-4# Drive MC Port Settings
Parameters to configure the standard telegram or custom telegram for the GE drive port.
O-40 Telegram Selection
Option: Function:
[1] * Standard telegram 1
[101] PPO 1 Enables use of freely configurable messages or standard messages for the Drive port.
[102] PPO 2
[103] PPO 3
[104] PPO 4
[105] PPO 5
[106] PPO 6
[107] PPO 7
[108] PPO 8
[200] Custom telegram 1
3.10.5 O-5# Digital/Bus
Parameters to configure the control word Digital/Bus merging.
O-50 Coasting Select
Option: Function:
Select control of the coasting function via the terminals (digital input) and/or via the network.
[0] Digit Input Activates Start command via a digital input.
[1] Bus Activates Start command via the serial communication port or network option module.
[2] Logic AND Activates Start command via the network/serial communication port, AND additionally via one of the
digital inputs.
[3] * Logic OR Activates Start command via the network/serial communication port OR via one of the digital inputs.
NB!
This parameter is active only when par. O-01 Control Site is set to [0] Digital and control word.
O-51 Quick Stop Select
Select control of the Quick Stop function via the terminals (digital input) and/or via the network.
Option: Function:
[0] Digital Input
[1] Bus
[2] Logic AND
[3] * Logic OR
NB!
This parameter is active only when par. O-01 Control Site is set to [0] Digital and control word.
AF-650 GP Programming Guide
119
3