Par. No. # Parameter description Default value 4-set-up Change during opera-
tion
Conver-
sion index
Type
C-0#
C-01 Jump Frequency From [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
C-02 Jump Speed From [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
C-03 Jump Speed To [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
C-04 Jump Frequency To [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
C-05 Multi-step Frequency 1 - 8 0.00 % All set-ups TRUE -2 Int16
C-2#
C-20 Jog Speed [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
C-21 Jog Speed [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
C-22 Jog Accel/Decel Time ExpressionLimit All set-ups TRUE -2 Uint32
C-23 Quick Stop Decel Time ExpressionLimit 2 set-ups TRUE -2 Uint32
C-3#
C-30 Frequency Command 2 [20] Digital Potentiometer All set-ups TRUE - Uint8
C-34 Frequency Command 3 [0] No function All set-ups TRUE - Uint8