Par. No. # Parameter description Default value 4-set-up Change during opera-
tion
Conver-
sion index
Type
H-0#
H-03 Restore Factory Settings [0] Normal operation All set-ups TRUE - Uint8
H-04 Auto-Reset (Times) [0] Manual reset All set-ups TRUE - Uint8
H-05 Auto-Reset (Reset Interval) 10 s All set-ups TRUE 0 Uint16
H-07 Accel/Decel Time 1 Type [0] Linear All set-ups TRUE - Uint8
H-08 Reverse Lock null All set-ups FALSE - Uint8
H-09 Start Mode [0] Disabled All set-ups FALSE - Uint8
H-2#
H-20 Motor Feedback Loss Function [2] Trip All set-ups TRUE - Uint8
H-21 Motor Feedback Speed Error 300 RPM All set-ups TRUE 67 Uint16
H-22 Motor Feedback Loss Timeout 0.05 s All set-ups TRUE -2 Uint16
H-4#
H-40 Configuration Mode null All set-ups TRUE - Uint8
H-41 Motor Control Principle null All set-ups FALSE - Uint8
H-42 Flux Motor Feedback Source [1] 24V encoder All set-ups FALSE - Uint8
H-43 Torque Characteristics [0] Constant torque All set-ups TRUE - Uint8
H-44 Constant or Variable Torque OL [0] High torque All set-ups FALSE - Uint8
H-45 Local Mode Configuration [2] As mode par H-40 All set-ups TRUE - Uint8
H-46 Back EMF at 1000 RPM ExpressionLimit All set-ups FALSE 0 Uint16
H-47 Motor Angle Offset 0 N/A All set-ups FALSE 0 Int16
H-5#
H-50 Motor Magnetisation at Zero Speed 100 % All set-ups TRUE 0 Uint16
H-51 Min Speed Normal Magnetising [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
H-52 Min Speed Normal Magnetising [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
H-53 Model Shift Frequency ExpressionLimit All set-ups FALSE -1 Uint16
H-55 U/f Characteristic - U ExpressionLimit All set-ups TRUE -1 Uint16
H-56 U/f Characteristic - F ExpressionLimit All set-ups TRUE -1 Uint16
H-6#
H-61 High Speed Load Compensation 100 % All set-ups TRUE 0 Int16
H-64 Resonance Dampening 100 % All set-ups TRUE 0 Uint16
H-65 Resonance Dampening Time Constant 5 ms All set-ups TRUE -3 Uint8
H-66 Min. Current at Low Speed 100 % All set-ups TRUE 0 Uint8
H-7#
H-70 Warning Current Low 0.00 A All set-ups TRUE -2 Uint32
H-71 Warning Current High Imax Value All set-up TRUE -2 Uint32
H-72 Warning Speed Low 0 RPM All set-ups TRUE 67 Uint16
H-73 Warning Speed High outputSpeedHighLimit All set-ups TRUE 67 Uint16
H-74 Warning Reference Low -999999.999 N/A All set-ups TRUE -3 Int32
H-75 Warning Reference High 999999.999 N/A All set-ups TRUE -3 Int32
H-76 Warning Feedback Low -999999.999 ReferenceFeedbackUnit All set-ups TRUE -3 Int32
H-77 Warning Feedback High 999999.999 ReferenceFeedbackUnit All set-ups TRUE -3 Int32
H-78 Missing Motor Phase Function null All set-ups TRUE - Uint8
H-8#
H-80 Function at Stop [0] Coast All set-ups TRUE - Uint8
H-81 Min Speed for Function at Stop [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
H-82 Min Speed for Function at Stop [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
H-83 Precise Stop Function [0] Precise ramp stop All set-ups FALSE - Uint8
H-84 Precise Stop Counter Value 100000 N/A All set-ups TRUE 0 Uint32
H-85 Precise Stop Speed Compensation Delay 10 ms All set-ups TRUE -3 Uint8
H-87 Load Type [0] Passive load All set-ups TRUE - Uint8
H-88 Minimum Inertia ExpressionLimit All set-ups FALSE -4 Uint32
H-89 Maximum Inertia ExpressionLimit All set-ups FALSE -4 Uint32
H-9#
H-95 KTY Sensor Type [0] KTY Sensor 1 All set-ups TRUE - Uint8
H-96 KTY Thermistor Input [0] None All set-ups TRUE - Uint8
H-97 KTY Threshold level 80 °C 1 set-up TRUE 100 Int16