Par. No. # Parameter description Default value 4-set-up Change during opera-
tion
Conver-
sion index
Type
EC-1#
EC-10 Signal Type [1] RS422 (5V TTL) All set-ups FALSE - Uint8
EC-11 Resolution (PPR) 1024 All set-ups FALSE 0 Uint16
EC-2#
EC-20 Protocol Selection [0] None All set-ups FALSE - Uint8
EC-21 Resolution (Positions/Rev) ExpressionLimit All set-ups FALSE 0 Uint32
EC-24 SSI Data Length 13 All set-ups FALSE 0 Uint8
EC-25 Clock Rate ExpressionLimit All set-ups FALSE 3 Uint16
EC-26 SSI Data Format [0] Gray code All set-ups FALSE - Uint8
EC-34 HIPERFACE Baudrate [4] 9600 All set-ups FALSE - Uint8
EC-6#
EC-60 Feedback Direction [0] Clockwise All set-ups FALSE - Uint8
EC-61 Feedback Signal Monitoring [1] Warning All set-ups TRUE - Uint8