Par. No. # Parameter description Default value 4-set-up Change during opera-
tion
Conver-
sion index
Type
SP-1#
SP-10 Line failure [0] No function All set-ups FALSE - Uint8
SP-11 Line Voltage at Input Fault ExpressionLimit All set-ups TRUE 0 Uint16
SP-12 Function at Line Imbalance [0] Trip All set-ups TRUE - Uint8
SP-2#
SP-23 Typecode Setting null 2 set-ups FALSE - Uint8
SP-24 Trip Delay at Current Limit 60 s All set-ups TRUE 0 Uint8
SP-25 Trip Delay at Torque Limit 60 s All set-ups TRUE 0 Uint8
SP-26 Trip Delay at Drive Fault ExpressionLimit All set-ups TRUE 0 Uint8
SP-28 Production Settings [0] No action All set-ups TRUE - Uint8
SP-3#
SP-30 Current Lim Cont, Proportional Gain 100 % All set-ups FALSE 0 Uint16
SP-31 Current Lim Contr, Integration Time 0.020 s All set-ups FALSE -3 Uint16
SP-4#
SP-40 VT Level 66 % All set-ups FALSE 0 Uint8
SP-41 Energy Savings Min. Magnetisation ExpressionLimit All set-ups TRUE 0 Uint8
SP-42 Energy Savings Min. Frequency 10 Hz All set-ups TRUE 0 Uint8
SP-43 Motor Cosphi ExpressionLimit All set-ups TRUE -2 Uint16
SP-5#
SP-50 RFI Filter [1] On 1 set-up FALSE - Uint8
SP-52 Fan Operation [0] Auto All set-ups TRUE - Uint8
SP-53 Fan Monitor [1] Warning All set-ups TRUE - Uint8
SP-56 Capacitance Output Filter 2.0 uF 1 set-up FALSE -7 Uint16
SP-57 Inductance Output Filter 7.000 mH 1 set-up FALSE -6 Uint16
SP-59 Actual Number of Inverter Units ExpressionLimit 1 set-up FALSE 0 Uint8
SP-6#
SP-63 Option Supplied by External 24VDC [1] Yes 2 set-ups FALSE - Uint8
SP-7#
SP-71 Accel Time 1 S-ramp Ratio at Accel. Start 50 % All set-ups TRUE 0 Uint8
SP-72 Accel Time 1 S-ramp Ratio at Accel. End 50 % All set-ups TRUE 0 Uint8
SP-73 Decel Time 1 S-ramp Ratio at Decel. Start 50 % All set-ups TRUE 0 Uint8
SP-74 Decel Time 1 S-ramp Ratio at Decel. End 50 % All set-ups TRUE 0 Uint8
SP-76 Accel/Decel Time 2 Type [0] Linear All set-ups TRUE - Uint8
SP-79 Accel Time 2 S-ramp Ratio at Accel. Start 50 % All set-ups TRUE 0 Uint8
SP-8#
SP-80 Accel Time 2 S-ramp Ratio at Accel. End 50 % All set-ups TRUE 0 Uint8
SP-81 Decel Time 2 S-ramp Ratio at Decel. Start 50 % All set-ups TRUE 0 Uint8
SP-82 Decel Time 2 S-ramp Ratio at Decel. End 50 % All set-ups TRUE 0 Uint8
SP-84 Accel/Decel Ramp 3 Type [0] Linear All set-ups TRUE - Uint8
SP-87 Accel Time 3 S-ramp Ratio at Accel. Start 50 % All set-ups TRUE 0 Uint8
SP-88 Accel Time 3 S-ramp Ratio at Accel. End 50 % All set-ups TRUE 0 Uint8
SP-89 Decel Time 3 S-ramp Ratio at Decel. Start 50 % All set-ups TRUE 0 Uint8
SP-9#
SP-90 Decel Time 3 S-ramp Ratio at Decel. End 50 % All set-ups TRUE 0 Uint8
SP-92 Accel/Decel Ramp 4 Type [0] Linear All set-ups TRUE - Uint8
SP-95 Accel Time 4 S-ramp Ratio at Accel. Start 50 % All set-ups TRUE 0 Uint8
SP-96 Accel Time 4 S-ramp Ratio at Accel. End 50 % All set-ups TRUE 0 Uint8
SP-97 Decel Time 4 S-ramp Ratio at Decel. Start 50 % All set-ups TRUE 0 Uint8
SP-98 Decel Time 4 S-ramp Ratio at Decel. End 50 % All set-ups TRUE 0 Uint8