3.18 Adv Parameter Data Set
3.19 LC-## Logic Controller
Parameter group related to programming the drive's built-in Logic Controller. The Logic Controller consists of a series of user defined actions (see par. LC-53) that
are executed when the corresponding user-defined events are met.
3.19.1 LC-0# LC Settings
Parameters to configure the activation, deactivations and reset of the Logic Controller (LC).
LC-00 Logic Controller Mode
Option: Function:
[0] * Off Disables the Logic Controller.
[1] On Enables the Logic Controller.
LC-01 Start Event
Option: Function:
[0] * False Select the boolean (TRUE or FALSE) input to activate Logic Controller.
False [0] enters the fixed value - FALSE
[1] True True [1] enters the fixed value - TRUE.
[2] Running Running [2] The motor is running.
[3] In range In range [3] The motor is running within the programmed current and speed ranges set in par.
H-70 Warning Current Low to par. H-73 Warning Speed High.
[4] On reference On reference [4] The motor is running on reference.
[5] Torque limit Torque limit [5] The torque limit, set in par. F-40 Torque Limiter (Driving) or par. F-41 Torque Limiter (Brak-
ing), has been exceeded.
[6] Current Limit Current limit [6] The motor current limit, set in par. F-43 Current Limit, has been exceeded.
[7] Out of current range Out of current range [7] The motor current is outside the range set in par. F-43 Current Limit.
[8] Below I low Below I low [8] The motor current is lower than set in par. H-70 Warning Current Low.
[9] Above I high Above I high [9] The motor current is higher than set in par. H-71 Warning Current High.
[10] Out of speed range Out of speed range [10] The speed is outside the range set in par. H-72 Warning Speed Low and par.
H-73 Warning Speed High.
[11] Below speed low Below speed low [11] The output speed is lower than the setting in par. H-72 Warning Speed Low.
[12] Above speed high Above speed high [12] The output speed is higher than the setting in par. H-73 Warning Speed High.
[13] Out of feedb. range Out of feedb. Range [13] The feedback is outside the range set in par. H-76 Warning Feedback Low and
par. H-77 Warning Feedback High.
[14] Below feedb. low Below feedb. Low [14] The feedback is below the limit set in par. H-76 Warning Feedback Low.
[15] Above feedb. high Above feedb. High [15] The feedback is above the limit set in par. H-77 Warning Feedback High.
[16] Thermal warning Thermal warning [16] The thermal warning turns on when the temperature exceeds the limit in the motor,
the frequency converter, the brake resistor or the thermistor.
[17] Line voltage out of range Mains out of range [17] The mains voltage is outside the specified voltage range.
[18] Reversing Reversing [18] The output is high when the frequency converter is running counter clockwise (the logical
product of the status bits “running” AND “reverse”).