[62] Comparator 2 See par. group LC-1#. If Comparator 2 is evaluated as TRUE, the output will go high. Otherwise, it will be
low.
[63] Comparator 3 See par. group LC-1#. If Comparator 3 is evaluated as TRUE, the output will go high. Otherwise, it will be
low.
[64] Comparator 4 See par. group LC-1#. If Comparator 4 is evaluated as TRUE, the output will go high. Otherwise, it will be
low.
[65] Comparator 5 See par. group LC-1#. If Comparator 5 is evaluated as TRUE, the output will go high. Otherwise, it will be
low.
[70] Logic Rule 0 See par. group LC-4#. If Logic Rule 0 is evaluated as TRUE, the output will go high. Otherwise, it will be
low.
[71] Logic Rule 1 See par. group LC-4#. If Logic Rule 1 is evaluated as TRUE, the output will go high. Otherwise, it will be
low.
[72] Logic Rule 2 See par. group LC-4#. If Logic Rule 2 is evaluated as TRUE, the output will go high. Otherwise, it will be
low.
[73] Logic Rule 3 See par. group LC-4#. If Logic Rule 3 is evaluated as TRUE, the output will go high. Otherwise, it will be
low.
[74] Logic Rule 4 See par. group LC-4#. If Logic Rule 4 is evaluated as TRUE, the output will go high. Otherwise, it will be
low.
[75] Logic Rule 5 See par. group LC-4#. If Logic Rule 5 is evaluated as TRUE, the output will go high. Otherwise, it will be
low.
[80] SL Digital Output A See par. LC-52 Logic Controller Action. The output will go high whenever the Logic Controller Action [38]
Set dig. out. A high is executed. The output will go low whenever the Logic Controller Action [32] Set dig.
out. A low is executed.
[81] SL Digital Output B See par. LC-52 Logic Controller Action. The input will go high whenever the Logic Controller Action [39]
Set dig. out. A high is executed. The input will go low whenever the Logic Controller Action [33] Set dig.
out. A low is executed.
[82] SL Digital Output C See par. LC-52 Logic Controller Action. The input will go high whenever the Logic Controller Action [40]
Set dig. out. A high is executed. The input will go low whenever the Logic Controller Action [34] Set dig.
out. A low is executed.
[83] SL Digital Output D See par. LC-52 Logic Controller Action. The input will go high whenever the Logic Controller Action [41]
Set dig. out. A high is executed. The input will go low whenever the Logic Controller Action [35] Set dig.
out. A low is executed.
[84] SL Digital Output E See par. LC-52 Logic Controller Action. The input will go high whenever the Logic Controller Action [42]
Set dig. out. A high is executed. The input will go low whenever the Logic Controller Action [36] Set dig.
out. A low is executed.
[85] SL Digital Output F See par. LC-52 Logic Controller Action. The input will go high whenever the Logic Controller Action [43]
Set dig. out. A high is executed. The input will go low whenever the Logic Controller Action [37] Set dig.
out. A low is executed.
[120] Local reference active Output is high when par. F-02 Operation Method = [2] Local or when par. F-02 Operation Method = [0]
Linked to hand auto at the same time as the Keypad is in Hand mode.
[121] Remote reference active Output is high when par. F-02 Operation Method = Remote [1] or Linked to hand/auto [0] while the
Keypad is in [Auto] mode.
[122] No alarm Output is high when no alarm is present.
[123] Start command active Output is high when there is an active Start command (i.e. via digital input bus connection or [Hand] or
[Auto]), and no Stop or Start command is active.
[124] Running reverse Output is high when the frequency converter is running counter clockwise (the logical product of the
status bits ‘running’ AND ‘reverse’).
[125] Drive in hand mode Output is high when the frequency converter is in [Handmode] (as indicated by the LED light above [Hand]).
[126] Drive in auto mode Output is high when the frequency converter is in [Hand] mode (as indicated by the LED light above [Auto]).