ÄKTA ready XL
O
perating Instructions
Original instructions
gelifesciences.com
*** TeDIS Valid on Date Printed Printed on: 15-09-2023 11:27:35 ***
185018004599

Table of Contents

Questions and Answers:

GE AKTA ready XL Specifications

General IconGeneral
BrandGE
ModelAKTA ready XL
CategoryMedical Equipment
LanguageEnglish

Summary

Introduction

About this manual

Details the purpose, scope, and typographical conventions used in the manual.

Important user information

Provides critical information for users, intended use, and prerequisites for operating the system safely.

Associated documentation

Lists system documentation such as P&ID, specifications, drawings, and BOM.

Abbreviations

Explains abbreviations used throughout the ÄKTA ready XL user documentation, including common technical terms.

Safety Instructions

About this chapter

Describes safety precautions, labels, symbols, emergency procedures, and recycling information.

Safety Precautions

Details general, personal protection, flammable liquids, installation, operation, and maintenance safety measures.

Emergency Procedures

Describes how to perform emergency shutdown, handle power failures, and restart the system.

Labels

Explains system nameplate labels, including serial number, type, power, and environmental data.

System Description

About this chapter

Provides an overview of the ÄKTA ready XL system's technical properties and flow kit details.

System Overview

Describes the ÄKTA ready XL system, its intended use, components, and operating modes.

System Components

Provides descriptions of ÄKTA ready XL components, including the control system.

Flow Kits

Provides descriptions of disposable flow kits and an overview of their components.

Process Control Software

Explains system control via software like UNICORN, covering methods, user access, and networks.

Installation

About this chapter

Describes how to transport, move, and set up the ÄKTA ready XL system for use.

Site Requirements

Details system dimensions, space, ambient environment, compressed air, and electrical power requirements.

Transport and Moving

Provides instructions and precautions for transporting the system, including moving the crate and removing the system.

Power Supply Connection

Details how the mains power supply must be connected and configured by authorized personnel.

Preparation

About this chapter

Provides information required to prepare the ÄKTA ready XL for operation.

Start System and Log On to Control Software

Guides users on starting the ÄKTA ready XL and logging into the UNICORN control software.

Install Disposable Flow Kits

Describes procedures for installing flow kits and gradient sections for isocratic and gradient setups.

Perform Flow Kit Installation Test

Describes how to test sensor and meter installation using UNICORN, generating a test report.

Prime to Remove Air

Explains how to remove air from the pump and flow path, especially after connecting new inlets or changing tanks.

Operation

About this chapter

Provides information to start, run, and shut down the ÄKTA ready XL system after a run.

Connect a Column

Outlines steps for connecting columns to ÄKTA ready XL using UNICORN, including pressure limit considerations.

Run a Method

Describes how to start, monitor, and evaluate a run using UNICORN control software.

Controlled Shutdown and Flow Kit Removal

Provides instructions for removing the disposable flow kit and shutting down the system and control software.

Maintenance

About this chapter

Provides instructions for user maintenance and information on preventive maintenance by service personnel.

Regular Maintenance

Details daily maintenance tasks, emphasizing keeping the system clean and dry.

Calibration of Level Sensors

Describes how to calibrate air trap level sensors using UNICORN software.

Troubleshooting

About this chapter

Provides information to identify and correct problems that may occur during ÄKTA ready XL operation.

System Troubleshooting

Addresses issues with computer communication, power failure, and compressed air supply, with corrective actions.

Valves and Flow Kit Troubleshooting

Covers troubleshooting for valve errors, failed flow kit installation tests, and low flow issues.

Reference Information

About this chapter

Provides reference information useful for installing, operating, maintaining, and troubleshooting the system.

Specifications

Details general specifications like dimensions, weight, power, frequency, and environmental conditions.

Chemical Resistance

Lists recommended cleaning agents and allowed chemicals for ÄKTA ready XL flow kits, with concentration limits.

Regulatory Information

Lists regulations and standards applicable to ÄKTA ready XL, including CE marking and UL listing.

Related product manuals