CHAPTER 1: INTRODUCTION SPECIFICATIONS
MM300 MOTOR MANAGEMENT SYSTEM – INSTRUCTION MANUAL 1–11
PROFIBUS (COPPER)
Modes:...................................................................... DPV0 slave, up to 1.5 Mbps DPV1 slave, up to 1.5 Mbps
Connector:.............................................................. 5-pin terminal
RS485 PORT
Port: ........................................................................... opto-isolated
Baud rates:............................................................. up to 115 kbps
Protocol: .................................................................. Modbus RTU, half-duplex
Maximum distance: ........................................... 1200 m
Isolation:.................................................................. 2 kV
USB PORT (GRAPHIC CONTROL PANEL ONLY)
Standard specification: .................................... Compliant with both USB 2.0 and USB 1.1
Data transfer rate:.............................................. USB device emulating serial communications port at 115
kbps