– 70 –
Checking the fl ame size
WARNING: If you attempt to measure the inner
cone of the fl ame, please use caution; burns could
result.
Check the inner cone of the fl ame. It should be
approximately
1
/
2
- to
3
/
4
-in. long for the bake and
broil burners.
If the fl ame size is incorrect, recheck all conversion
steps.
When all adjustments are made and the results
are satisfactory:
Replace the orifi ce fi tting cover.1.
Replace the oven baffl e (fl ame spreader).2.
Replace the oven bottom.3.
In some cases, with L.P. gas, some yellow tipping on
the outer cone is normal. Foreign particles in the gas
line may cause an orange fl ame at fi rst, but this will
soon disappear.
Turn on the gas. 4.
Turn on the electricity.5.
Reinstall the oven door. 6.
Turn on the bake or broil burner. 7.
Note: As you watch the fl ame with the oven door
closed, check the following through the oven door
window:
a. If the fl ames are yellow, open the air
shutter more.
b. If the fl ames blow away or fl utter from the
burner, close the air shutter more.
1/2" TO 3/4"
QUEMADOR PARA
HORNEAR/ASAR
1/2″ to 3/4″
Inner Cone of Flame
Oven Broiler Burner
“A” YELLOW
FLAMES
Call for Service
“B” SLIGHT
YELLOW TIPPING
Normal for L.P. Gas
“C”
SOFT BLUE FLAMES
Normal for Natural Gas
Burner Output Ratings
(Continued next page)
Model PGS908
Burner Output Rating - Natural Gas 5 in. W.C.P.
Burner BTU Rate Orifi ce Size
RF 15,000 No. 49
RR 5,000 No. 56
LF 11,000 No. 52
LR 9,100 No. 54
Bake 15,000
Broil 12,000
Burner Output Rating - L.P. Gas 10 in. W.C.P.
Burner BTU Rate Orifi ce Size
RF 13,000 No. 59
RR 5,200 No. 69
LF 11,000 No. 63
LR 8,000 No. 65
Bake 15,000
Broil 12,000
Models PGS968
Burner Output Rating - Natural Gas 4 in. W.C.P.
Burner BTU Rate Orifi ce Size
RF 15,000 No. 49
RR 6,000 No. 56
LF 11,000 No. 52
LR 9,100 No. 54
Bake 15,000
Broil 12,000
Burner Output Rating - L.P. Gas 10 in. W.C.P.
Burner BTU Rate Orifi ce Size
RF 13,000 No. 59
RR 5,200 No. 69
LF 9,100 No. 63
LR 8,000 No. 65
Bake 15,000
Broil 12,000