EasyManuals Logo

GEA T-smart 7 User Manual

GEA T-smart 7
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
12 Decommissioning
12.1 Safety instructions
For shutting down, the following principles apply:
Switch off the compressed air.
Switch off the component with the main switch.
Padlock the main switch (if fitted) in the off position to prevent it from being
switched back on. The key to the padlock must be deposited with the person
responsible until the machine is restarted.
For longer periods of standstill, observe the storage conditions, see
Chapter 4, Page 21.
12.2 Disposal
12.2.1 General notes
Dispose of the component in an environmentally safe manner. Observe the
statutory waste disposal regulations applicable at the place of installation.
The component consists of the following materials:
Metals
Synthetic materials
Electronic parts
Lubricants containing oil and grease
Separate the different materials and dispose of them correctly sorted. Also
observe the instructions regarding disposal in the operating instructions for the
individual components.
12.2.2 Valve Actuator Disposal
Danger
The spring forces in the actuator can be as high as 24 kN.
The pre-stressed spring can cause serious personal injury or death.
► Never open the actuator.
► GEA Tuchenhagen accepts unopened actuators and arranges for proper
disposal free of charge.
Carry out the following steps:
1.
Remove the actuator.
2.
Pack the actuator safely and send it to GEA Tuchenhagen GmbH.
®
Done
Decommissioning
Safety instructions
430BAL009990EN_2
54 30.01.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GEA T-smart 7 and is the answer not in the manual?

GEA T-smart 7 Specifications

General IconGeneral
BrandGEA
ModelT-smart 7
CategoryControl Unit
LanguageEnglish

Related product manuals