104 AFE200 • Instruction Manual
12 - ACTIVE CURR CONFIG
Menu PAR Description UM Type FB BIT Def Min Max Acc
12.1 2350 Active curr lim Pos A FLOAT 16/32 CALCF 0.0 CALCF ERWS
Setting of the drive active current limit for the positive current direction.
Menu PAR Description UM Type FB BIT Def Min Max Acc
12.2 2352 Active curr lim Neg A FLOAT 16/32 CALCF 0.0 CALCF ERWS
Setting of the drive active current limit for the negative current direction.
Menu PAR Description UM Type FB BIT Def Min Max Acc
12.3 2354 Active curr lim sel ENUM Spento 0 2 ERWZ
Setting of the type of behaviour of the drive in the current limit condition.
0 Off
1 Act clim +/-
2 Act clim src
If set to 0 no specic type of current limitation is set.
If set to 1 the active positive current limit is Active curr lim Pos (PAR 2350) and the
active negative current limit is Active curr lim Neg (PAR 2352).
If set to 2 the active current limits are symmetrical. The value of parameter PAR 2358
is used as the active current reference value (default = Zero)