AFE200 • Instruction Manual 105
Torque curr lim Pos
Torque curr lim Neg
speed
torque
Torque curr lim Pos
Torque curr lim Neg
Menu PAR Description UM Type FB BIT Def Min Max Acc
12.4 2358 Active curr lim src LINK 16/32 6000 0 16384 ERWZ
L�LIM
Selection of the origin (source) to be used to set the active current limit.
The signals that can be associated with the function can be selected from the “L_LIM”
selection list.
Menu PAR Description UM Type FB BIT Def Min Max Acc
12.5 2360 Active climPos Inuse A FLOAT 16/32 0.0 0.0 0.0 ER
The positive current limit value currently in use is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc
12.6 2362 Active climNeg Inuse A FLOAT 16/32 0.0 0.0 0.0 ER
The negative current limit value currently in use is displayed.