Loading...
62 AFE200 • Instruction Manual
T+ T- EN LOC ILim n:0 AL
STARTUP WIZARD
Set DC link voltage ?
E=Yes Down=Next
E
T+ T- EN LOC ILim n:0 AL
S E Q . 0 1
PA R : 6 0 0
Dig DC voltage ref
650V
Def: 650
T+ T- EN LOC ILim n:0 AL
1 3 . 0 1
PA R : 1 0 0
Rated voltage
+ V
Def: +400
000000400
E
T+ T- EN LOC ILim n:0 AL
S E Q . 0 1
PA R : 6 0 0
Dig DC voltage ref
V
Def: 650
0000650
T+ T- EN LOC ILim n:0 AL
S E Q . 0 1
PA R : 6 0 0
Dig DC voltage ref
V
Def: 650
0000651
E
E
E
T+ T- EN LOC ILim n:0 AL
S E Q . 0 2
PA R : 6 0 2
Acceleration time DC
5.0 s
Def: 5.0
T+ T- EN LOC ILim n:0 AL
1 3 . 0 1
PA R : 1 0 0
Rated voltage
+ V
Def: +400
000000400
E
T+ T- EN LOC ILim n:0 AL
S E Q . 0 2
PA R : 6 0 2
Acceleration time DC
s
Def: 5.0
000005.0
T+ T- EN LOC ILim n:0 AL
S E Q . 0 2
PA R : 6 0 2
Acceleration time DC
s
Def: 5.0
000005.1
E
E
E
T+ T- EN LOC ILim n:0 AL
S E Q . 0 3
PA R : 6 0 4
Deceleration time DC
5.0 s
Def: 5.0
T+ T- EN LOC ILim n:0 AL
1 3 . 0 1
PA R : 1 0 0
Rated voltage
+ V
Def: +400
000000400
E
T+ T- EN LOC ILim n:0 AL
S E Q . 0 3
PA R : 6 0 4
Deceleration time DC
s
Def: 5.0
000005.0
T+ T- EN LOC ILim n:0 AL
S E Q . 0 3
PA R : 6 0 4
Deceleration time DC
s
Def: 5.0
000005.1
E
E
At the end of the procedure, proceed to Step 5.
Step 5 - Saving parameters (Save parameters)
To save the new parameter settings, so that they are maintained also after power-
off, proceed as follows:
T+ T- EN LOC ILim n:0 AL
STARTUP WIZARD
Save parameters ?
E=Yes Down=Next
E
T+ T- EN LOC ILim n:0 AL
Save parameters
S E Q . 0 1
PA R : 5 5 0
Press E to execute
E
T+ T- EN LOC ILim n:0 AL
Save parameters
S E Q . 0 1
PA R : 5 5 0
In progress
T+ T- EN LOC ILim n:0 AL
Save parameters
S E Q . 0 1
PA R : 5 5 0
Done
T+ T- EN LOC ILim n:0 AL
STARTUP WIZARD
End of sequence !
Up=Back Down=Exit

Table of Contents