70 AFE200 • Instruction Manual
2 - DRIVE INFO
This menu displays the information for identifying and conguring the drive.
Menu PAR Description UM Type FB BIT Def Min Max Acc
2.1 482 Drive size UINT16 0 0 0 RS
The drive size identication code is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc
2.2 484 Drive family ENUM No Power 0 0 RS
The available mains voltage is displayed (e.g. 400V). The undervoltage alarm refers to
this voltage value.
The condition No power occurs when the regulation board has just left from produc-
tion and has never been congured for any power. The conguration adjustment for
a given power is achieved by linking it to a power board and running a Save param-
eters.
0 No Power
1 380V..480V
2 500V..575V
3 690V
4 230V
5 270V
Menu PAR Description UM Type FB BIT Def Min Max Acc
2.3 486 Drive region ENUM EU 0 1 R
Setting of the geographical area in which the drive is to be used (Europe or USA).
This setting determines the factory voltage and power supply frequency values (e.g.
when set to 0 the default voltage is 400V and frequency 50Hz).
0 EU
1 USA
Menu PAR Description UM Type FB BIT Def Min Max Acc
2.4 488 Drive cont current A FLOAT CALCF 0.0 0.0 RZS
The current that the drive can deliver continuously according to size, supply voltage and
programmed switching frequency is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc
2.5 490 Firmware ver.rel UINT16 0 0 0 R
The version number and release number of the drive rmware are displayed. On the
keypad these are displayed in the version.release format. The parameter reading from
the serial communication device or eldbus returns the version in the high byte and
the release in the low byte.
Menu PAR Description UM Type FB BIT Def Min Max Acc
2.6 496 Firmware type UINT16 0 0 0 R
The type of rmware installed in the drive is displayed.