AFE200 • Instruction Manual 69
000000000011
Active DI 1Active DI 2
Menu PAR Description UM Type FB BIT Def Min Max Acc
1.21 1400 Digital output X mon UINT16 0 0 0 R
The status of the digital outputs of the expansion card is displayed. It can also be read
via a serial line or eldbus. The data are contained in a word, where each bit is 1 if
voltage is supplied to the corresponding input terminal.
0 Output disabled
1 Output enabled
I.e. : 000000000011
000000000011
Active DO 1Active DO 2
Menu PAR Description UM Type FB BIT Def Min Max Acc
1.22 1060 Sequencer status ENUM 16 Inizio 0 0 ER
Drive state parameter. Provides the drive’s operating and activation state and is
responsible for protection and alarm conditions, the command sequence and reset
condition.
0 Init
1 Wait Vdc Ok
2 Delay
3 Offset Calc
4 Ready
5 Run
6 Alarm Disabled
7 Alm End Action
8 Alm return
9 Alm no restart